Current flow through grounding components may occur if.
Magnetic flow meter grounding rings.
For example when measuring strong corrosive medium the pipe will be made of pvc or ptfe plated electrode which is precious metal especially for large diameter.
Multiple magmeters are used in a system.
Many of the exotic alloy grounding rings are maintained in stock in a variety of materials up to 6.
Other sizes are.
For example grounding rings are very effective when utilized before and after a magnetic flow meter fitting between flanges to ground out unwanted signals in the fluid that can cause inaccuracies in the flow meter s readings.
Ground rings or lining protectors should be connected as shown in figure 5.
In addition to providing the required solution ground placing this grounding ring on the upstream side of the flow tube also provides a fair degree of liner protection to the leading edge of the flow tube s liner when used in moderately abrasive applications.
In some occasions it is not suitable to increase the grounding ring.
In this situation ground rings provide a path to shunt the current around the fluid in the magmeter.
Type e grounding rings utilize customer supplied bolts rather then grounding wires or grounding straps.
This lets the magnetic flowmeter read a stable zero flow and achieve accurate measurement in flow conditions.
It is very important to connect both ground rings to the sensor case to minimize the current flow through the process fluid near the electrodes.
Grounding rings are flat wafer style rings designed to be installed between the flanges and a mag910 e mag920 or mag930 series inline electromagnetic flow meter flange face.
Using two ground rings will provide a path to shunt the current around the fluid in the magmeter.
For example grounding rings are very effective when utilized before and after a magnetic flow meter fitting between flanges to ground out unwanted signals in the fluid that can cause inaccuracies in the flow meter s readings.
The size of the grounding rings should always match the meter size as opposed to the original pipe size for installation with inline.
The use method of grounding ring of the electromagnetic flow meter.
Many of the exotic alloy grounding rings are maintained in stock in a variety of materials up to 6.
The grounding ring typically installs on the upstream side of the magnetic flow meter.
Result is usually not an inaccurate flow measurement but rather an unstable flow measurement that can make control difficult or impossible.